10,277 research outputs found

    Molecular Memory with Atomically-Smooth Graphene Contacts

    Full text link
    We report the use of bilayer graphene as an atomically-smooth contact for nanoscale devices. A two-terminal Bucky ball (C60) based molecular memory is fabricated with bilayer graphene as a contact on the polycrystalline nickel electrode. Graphene provides an atomically-smooth covering over an otherwise rough metal surface. The use of graphene additionally prohibits the electromigration of nickel atoms into the C60 layer. The devices exhibit a low-resistance state in the first sweep cycle and irreversibly switch to a high resistance state at 0.8-1.2 V bias. The reverse sweep has a hysteresis behavior as well. In the subsequent cycles, the devices retain the high-resistance state, thus making it write-once read-many memory (WORM). The ratio of current in low-resistance to high-resistance state is lying in 20-40 range for various devices with excellent retention characteristics. Control sample without the bilayer graphene shows random hysteresis and switching.Comment: 13 pages and 4 figure

    Wireless Health Monitoring using Passive WiFi Sensing

    Full text link
    This paper presents a two-dimensional phase extraction system using passive WiFi sensing to monitor three basic elderly care activities including breathing rate, essential tremor and falls. Specifically, a WiFi signal is acquired through two channels where the first channel is the reference one, whereas the other signal is acquired by a passive receiver after reflection from the human target. Using signal processing of cross-ambiguity function, various features in the signal are extracted. The entire implementations are performed using software defined radios having directional antennas. We report the accuracy of our system in different conditions and environments and show that breathing rate can be measured with an accuracy of 87% when there are no obstacles. We also show a 98% accuracy in detecting falls and 93% accuracy in classifying tremor. The results indicate that passive WiFi systems show great promise in replacing typical invasive health devices as standard tools for health care.Comment: 6 pages, 8 figures, conference pape

    Comparison of two methods of noise power spectrum determinations of medical radiography systems

    Get PDF
    Noise in medical images is recognized as an important factor that determines the image quality. Image noise is characterized by noise power spectrum (NPS). We compared two methods of NPS determination namely the methods of Wagner and Dobbins on Lanex Regular TMG screen-film system and Hologic Lorad Selenia full field digital mammography system, with the aim of choosing the better method to use. The methods differ in terms of various parametric choices and algorithm implementations. These parameters include the low pass filtering, low frequency filtering, windowing, smoothing, aperture correction, overlapping of region of interest (ROI), length of fast Fourier transform, ROI size, method of ROI normalization, and slice selection of the NPS. Overall, the two methods agreed to the practical value of noise power spectrum between 10 -3-10-6mm2 over spatial frequency range 0-10mm-1
    corecore